Results 1 - 20 de 57
Filter
1.
J. optom. (Internet) ; 17(3): [100497], jul.-sept2024. graf, tab
Article in English | IBECS | ID: ibc-231871

ABSTRACT

Purpose: To compare the eye defocus curves (DCs) obtained with stimuli on red, green, and white backgrounds and to investigate the applicability of the duochrome test (DT) in different age groups. Methods: 12 elderly (ELD: 59.3 ± 3.9 years) and 8 young (YG: 22.1 ± 1.1 years) subjects were recruited. An optometric assessment with the DT was carried out to obtain the subjective refraction at distance. DCs at distance on green, white, and red backgrounds were measured and the following parameters were deduced: dioptric difference between red-green, green-white, red-white focal positions (minima of the DCs), best corrected visual acuity (BCVA), and widths of the DCs for red, green, and white. Results: The DC difference between the green-white focal positions (mean ± standard deviation) was -0.12±0.17 diopters (D) (ELD, p = 0.012) and -0.11±0.12 D (YG, p = 0.039), while the red-white difference was not statistically significant. The DC red-green difference was 0.20±0.16 D (ELD, p = 0.002) and 0.18±0.18 D (YG, p = 0.008). The ELD BCVA with green background was significantly worse than BCVA with red (p = 0.007) and white (p = 0.007). The mean value of the DC's width in ELD for green (1.01±0.36 D) was higher than for red (0.77±0.21 D) and for white (0.84±0.35 D), but with no statistical significance. Conclusion: Both age groups showed a slight focusing preference for red when using white light. Moreover, ELD showed a worse BCVA with a green compared to a red background. Despite these results deduced by DC analyses, these aspects do not compromise the possibility of using the DT in clinical practice both in the young and in the elderly. Furthermore, the difference of about 0.20 D between red-green DC in both groups confirms the clinical appropriateness of the widespread use of 0.25 D step as the standard minimum difference in power between correcting lenses.(AU)


Subject(s)
Humans , Male , Female , Young Adult , Aged , Vision, Ocular , Visual Acuity , Fundus Oculi , Contact Lenses , Vision Tests
2.
Cont Lens Anterior Eye ; : 102156, 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38641525

ABSTRACT

It is important to be able to measure the range of clear focus in clinical practice to advise on presbyopia correction techniques and to optimise the correction power. Both subjective and objective techniques are necessary: subjective techniques (such as patient reported outcome questionnaires and defocus curves) assess the impact of presbyopia on a patient and how the combination of residual objective accommodation and their natural DoF work for them; objective techniques (such as autorefraction, corneal topography and lens imaging) allow the clinician to understand how well a technique is working optically and whether it is the right choice or how adjustments can be made to optimise performance. Techniques to assess visual performance and adverse effects must be carefully conducted to gain a reliable end-point, considering the target size, contrast and illumination. Objective techniques are generally more reliable, can help to explain unexpected subjective results and imaging can be a powerful communication tool with patients. A clear diagnosis, excluding factors such as binocular vision issues or digital eye strain that can also cause similar symptoms, is critical for the patient to understand and adapt to presbyopia. Some corrective options are more permanent, such as implanted inlays / intraocular lenses or laser refractive surgery, so the optics can be trialled with contact lenses in advance (including differences between the eyes) to better communicate with the patient how the optics will work for them so they can make an informed choice.

3.
Brain Sci ; 14(3)2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38539623

ABSTRACT

A timely detection of visual hemifield deficits (VHFDs; hemianopias or quadrantanopias) is critical for both the diagnosis and treatment of stroke patients. The present study determined the sensitivity and specificity of four qualitative visual field tests, including face description, confrontation tests (finger wiggle), and kinetic boundary perimetry, to screen large and dense VHFDs in right-brain-damaged (RBD) stroke patients. Previously, the accuracy of qualitative visual field tests was examined in unselected samples of patients with heterogeneous aetiology, in which stroke patients represented a very small fraction. Building upon existing tests, we introduced some procedural ameliorations (incl. a novel procedure for kinetic boundary perimetry) and provided a scoresheet to facilitate the grading. The qualitative visual field tests' outcome of 67 consecutive RBD stroke patients was compared with the standard automated perimetry (SAP; i.e., reference standard) outcome to calculate sensitivity and specificity, as well as positive and negative predictive values (PPV and NPV), both for each individual test and their combinations. The face description test scored the lowest sensitivity and NPV, while the kinetic boundary perimetry scored the highest. No test returned false positives. Combining the monocular static finger wiggle test (by quadrants) and the kinetic boundary perimetry returned the highest sensitivity and specificity, in line with previous studies, but with higher accuracy (100% sensitivity and specificity). These findings indicate that the combination of these two tests is a valid approach with RBD stroke patients, prompting referral for a formal visual field examination, and representing a quick, easy-to-perform, and inexpensive tool for improving their care and prognosis.

4.
Cont Lens Anterior Eye ; : 102137, 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38485618

ABSTRACT

A common non-spectacle strategy to correct presbyopia is to provide simultaneous images with multifocal optical designs. Understanding the neuroadaptation mechanisms behind multifocal devices usage would have important clinical implications, such as predicting whether patients will be able to tolerate multifocal optics. The aim of this study was to evaluate the brain correlates during the initial wear of multifocal contact lenses (CLs) using high-density visual evoked potential (VEP) measures. Fifteen presbyopes (mean age 51.8 ±â€¯2.6 years) who had previously not used multifocal CLs were enrolled. VEP measures were achieved while participants looked at arrays of 0.5 logMAR Sloan letters in three different optical conditions arranged with CLs: monofocal condition with the optical power appropriate for the distance viewing; multifocal correction with medium addition; and multifocal correction with low addition. An ANOVA for repeated measures showed that the amplitude of the C1 and N1 components significantly dropped with both multifocal low and medium addition CL conditions compared to monofocal CLs. The P1 and P2 components showed opposite behavior with an increase in amplitudes for multifocal compared to monofocal conditions. VEP data indicated that multifocal presbyopia corrections produce a loss of feedforward activity in the primary visual cortex that is compensated by extra feedback activity in extrastriate areas only, in both early and late visual processing.

5.
Sci Rep ; 14(1): 2516, 2024 01 30.
Article in English | MEDLINE | ID: mdl-38291100

ABSTRACT

To evaluate the agreement and repeatability of an automated topography-based method for non-invasive break-up time (NIBUT) analyses in comparison with two other NIBUT procedures, the fluorescein procedure (fBUT), and with the manual assessment with the same device. In the first experiment, a semi-randomised crossover study was performed on forty-three participants (23.1 ± 2.1 years). NIBUT measurements were collected in a randomised order, in both eyes of participants with EasyTear View + (Easytear, Rovereto), Polaris, and Sirius + (CSO, Firenze). Then a fBUT was collected. The overall measurement procedure was repeated in a further session (retest) on the same day. In a second experiment, a retrospective randomised crossover study was performed on eighty-five NIBUT videos previously recorded by the Sirius+. Two observers assessed manually the videos and the NIBUTs were compared with the automatic ones. In the first experiment, ANOVA showed a significant difference between the four measures in both eyes (p < 0.001). Significant differences were found in the paired comparisons between each NIBUT procedure and fBUT (Wicoxon; p < 0.05). Sirius+ resulted in agreement only with Polaris in the left eye. Correlations between all NIBUT procedures resulted in statistical significance in both eyes. All procedures showed very good test-rest reliability. In the second experiment, a significant correlation between automated and manual NIBUT was found, but also a significant statistical difference between the two measurements, although clinically negligible (0.3 s). The investigated NIBUT devices perform differently from each other (and from fBUT), so they cannot be considered interchangeable. The automated measure of NIBUT with Sirius+ has a negligible clinical difference compared to manual assessment on the same device.


Subject(s)
Dry Eye Syndromes , Lacerations , Humans , Dry Eye Syndromes/diagnosis , Eye , Fluorescein , Reproducibility of Results , Retrospective Studies , Tears , Cross-Over Studies
7.
J Optom ; 17(3): 100497, 2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38128434

ABSTRACT

PURPOSE: To compare the eye defocus curves (DCs) obtained with stimuli on red, green, and white backgrounds and to investigate the applicability of the duochrome test (DT) in different age groups. METHODS: 12 elderly (ELD: 59.3 ± 3.9 years) and 8 young (YG: 22.1 ± 1.1 years) subjects were recruited. An optometric assessment with the DT was carried out to obtain the subjective refraction at distance. DCs at distance on green, white, and red backgrounds were measured and the following parameters were deduced: dioptric difference between red-green, green-white, red-white focal positions (minima of the DCs), best corrected visual acuity (BCVA), and widths of the DCs for red, green, and white. RESULTS: The DC difference between the green-white focal positions (mean ± standard deviation) was -0.12±0.17 diopters (D) (ELD, p = 0.012) and -0.11±0.12 D (YG, p = 0.039), while the red-white difference was not statistically significant. The DC red-green difference was 0.20±0.16 D (ELD, p = 0.002) and 0.18±0.18 D (YG, p = 0.008). The ELD BCVA with green background was significantly worse than BCVA with red (p = 0.007) and white (p = 0.007). The mean value of the DC's width in ELD for green (1.01±0.36 D) was higher than for red (0.77±0.21 D) and for white (0.84±0.35 D), but with no statistical significance. CONCLUSION: Both age groups showed a slight focusing preference for red when using white light. Moreover, ELD showed a worse BCVA with a green compared to a red background. Despite these results deduced by DC analyses, these aspects do not compromise the possibility of using the DT in clinical practice both in the young and in the elderly. Furthermore, the difference of about 0.20 D between red-green DC in both groups confirms the clinical appropriateness of the widespread use of 0.25 D step as the standard minimum difference in power between correcting lenses.

8.
J. optom. (Internet) ; 16(3): 189-198, July - September 2023. tab, graf
Article in English | IBECS | ID: ibc-222227

ABSTRACT

Purpose This study aimed to translate the Convergence Insufficiency Symptom Survey (CISS) into the Italian language and assess psychometric properties of the translated questionnaire (CISS_I). Methods The CISS_I was arranged according to guidelines for a comprehensive multistep methodologic process for translating, adapting, and validating psychometric instruments in health care research. The CISS_I questionnaire was administered to 103 volunteers (21.8 ± 2.2 years), students in higher education, at two different times. A complete optometric evaluation was performed including subjective refraction, best corrected visual acuity, near point of convergence, prism fusional ranges to blur, diplopia and recovery, TNO stereo test and prism cover test for measurement of heterophoria. Results The performance of the CISS_I in terms of validity showed some points of weakness. Sensitivity was 42%, specificity was 74%, positive predictive value was 27% and negative predictive value was 85%. The area under the ROC curve was 0.672. On the contrary, the results showed good internal consistency of the CISS_I (Cronbach's alpha - α=0.89) and good test-retest reliability (ICC = 0.92). Rasch analysis showed good model fit (all items, except one, with infit and outfit mean square between 0.7 and 1.3), good measurement precision (person separation = 2.66) and good targeting –0,81 logits but also some evidence of multidimensionality. Conclusions The CISS_I showed some point of weakness in terms of validity but also good psychometric properties and has been shown to be applicable to an Italian speaking population to quantify the visual discomfort associated with near vision in higher education students. The results show that high CISS_I score is not necessarily linked to convergence insufficiency, while low scores can exclude the presence of this anomaly...(AU)


Subject(s)
Humans , Young Adult , Ocular Motility Disorders , Symptom Assessment , Vision, Ocular , Surveys and Questionnaires , Translating
9.
Clin Optom (Auckl) ; 15: 105-117, 2023.
Article in English | MEDLINE | ID: mdl-37181864

ABSTRACT

Purpose: To investigate and compare the degradation of visual acuity (VA) in myopic presbyopes due to lens-induced astigmatism at near and at far distance. Patients and Methods: Fourteen corrected myopic presbyopes were recruited. VA (logarithm of the minimum angle of resolution) was measured binocularly for different conditions of lens-induced astigmatism: cylindrical powers of -0.25, -0.50, -0.75, -1.00, -1.50, and -2.00 diopters (and positive spherical power of half the cylindrical power) with two axis orientations (with-the-rule WTR and against-the-rule ATR) were added to their optical correction. Measurements were carried out at far and near distance both in photopic and mesopic conditions, and for high and low contrast (HC/LC) stimuli. The paired Wilcoxon signed-rank statistics test was used to evaluate difference between conditions. Results: The measured VA as a function of the lens-induced astigmatism was described by regression lines in all investigated experimental conditions. The angular coefficients (slopes) of these lines represent the VA degradation, ie, the variation in logMAR corresponding to the addition of 1.00 diopters of cylindrical power. In photopic HC conditions, the VA degradation is significantly more pronounced at far distance than at near distance (0.22±0.06 diopters-1 vs 0.15±0.05 diopters-1, p = 0.0061 in WTR conditions; 0.18±0.06 diopters-1 vs 0.12±0.05 diopters-1, p = 0.0017 in ATR conditions), although VAs at near and at far with zero cylinder were similar (-0.14±0.10 vs -0.14±0.08, p = 0.824). Conclusion: The better tolerance to lens-induced astigmatism blur at near than at far distance in photopic conditions with HC stimuli is tentatively attributed to a possible experience-mediated neural compensation associated to the tendency of the eye toward an inherent astigmatism at near.

10.
Cont Lens Anterior Eye ; 46(3): 101842, 2023 06.
Article in English | MEDLINE | ID: mdl-37024414

ABSTRACT

PURPOSE: To translate and validate an Italian version of the CLDEQ-8 (CLDEQ-8_IT). METHODS: The study was carried out in two phases. In the first phase, a cross-cultural adaptation of CLDEQ-8 to Italian was performed by forward and backward translation in sequence. In the second phase, a multi-centre study was conducted for the validation of the questionnaire. Validity CLDEQ-8_IT was evaluated against three gestalt questions: overall opinion of soft contact lenses (CLs), global self-assessments of eye sensitivity and eye dryness. Reliability was evaluated by test-retest assessment in a subgroup of subjects. Finally, the psychometric properties of CLDEQ-8_IT were explored by Rasch analysis. RESULTS: Two hundred and forty soft CL wearers, fluent Italian speakers (73 males and 167 females), between 18 and 70 years of age were enrolled. A significant correlation was found between CLDEQ-8_IT and each of the three Gestalt questions. The cutoff score of 12 points demonstrated the best balance between sensitivity and specificity in differentiating wearers grading their CLs as "Excellent/Very good" from those reporting their overall opinion as "Good/Fair/Poor". The Intraclass Correlation Coefficient between test and retest was 0.88 (95% CI: 0.81-0.92). Finally, infit and outfit statistics using Rasch analysis for the 8 items were in a good range, however Principal Components Analysis revealed a certain degree of multi-dimensionality of the instrument. Also, item 8 analysis could be computed after merging the last two response categories. CONCLUSION: The CLDEQ-8_IT showed very good validity and reliability in measuring symptoms of CL wearers, comparable to the original English language version. A cut-off of 12 was confirmed as yielding the best balance between sensitivity and specificity in detecting CL wearers who could benefit from clinical management of their CL-related symptoms. Collapsing of the response options 5 and 6 in the last item of questionnaire could optimise its functioning.


Subject(s)
Contact Lenses, Hydrophilic , Dry Eye Syndromes , Male , Female , Humans , Reproducibility of Results , Surveys and Questionnaires , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Language
12.
Ophthalmic Physiol Opt ; 43(4): 629-639, 2023 07.
Article in English | MEDLINE | ID: mdl-36999924

ABSTRACT

PURPOSE: To develop a series of equivalent passages of text in Italian, according to the principles of the Wilkins Rate of Reading Test (WRRT), suitable for both clinical examination and scientific research when equivalent stimuli are needed to compare performance in repeated-measure designs. METHOD: Fifteen high-frequency Italian words (matched for grammatical class and length to the English WRRT) were used to generate 15 different 10-line meaningless passages, according to the design principles of the English WRRT. Thirty-two healthy Italian-speaking higher education students read the passages aloud according to a fixed randomisation schedule. Performance was recorded digitally to measure reading speed and accuracy offline. Equivalence between the passages and the practice and fatigue effects for both reading speed and accuracy were examined as well as test-retest reliability. RESULTS: No significant difference in reading speed and accuracy was found between the passages. There was a significant practice effect on reading speed but not accuracy, with the first presented passage read significantly slower than the others. There was no evidence of a fatigue effect. Reading speed, the reference metric for the WRRT, showed good test-retest reliability. CONCLUSIONS: The passages of the Italian version of the WRRT were equivalent to each other. The practice effect suggests that familiarisation with the test (i.e., reading at least one matrix of words) should be carried out before consecutive/repeated reading of different passages for experimental or clinical purposes.


Subject(s)
Optometry , Reading , Humans , Reproducibility of Results , Italy , Students
13.
Cont Lens Anterior Eye ; 46(2): 101822, 2023 04.
Article in English | MEDLINE | ID: mdl-36804937

ABSTRACT

INTRODUCTION: Contact lens (CL) practice is an ever-changing field with clinical knowledge, techniques and equipment continuously evolving. These new developments are backed with clinical trials and research to ensure that practitioners feel confident that there is an evidence base to support these advances. Evidence-based practice is now a crucial part of CL practice, and its importance also filters down to CL education. For example, lectures are one of the most popular tools for an educator but, is standing at the front of a lecture theatre full of students a more effective way of teaching than providing the same material for students to read by themselves? What evidence exists specific to CL education? METHOD: An expert panel of educators completed a comprehensive literature review of current evidence of teaching methods in CL training, or if not available then what can be learnt from other health care professional training that could be potentially applicable to CL education. RESULTS: Due to the amount of evidence available in the overall subject area relating to healthcare education, the initial plan of compiling evidence into one narrative review paper was discarded in favour of producing two linked papers. Here, the first paper details definitions of terminology, and also teaching methods. The second paper focuses on assessment and specific clinical training required to attain CL practice competency. In this first paper, no direct evidence of the spreading and benefit of new education strategies evidence such as flipped classrooms, spaced learning, test-enhanced learning, group work, CBL, PBL, TBL, and reflective practice in CL education was found. The only technique that was widely used in the CL field was case reports and the group discussion of them. Nevertheless, the authors found a consensus of opinion from other disciplines that are transferable to CL teaching and could help students meet the intended learning outcomes. CONCLUSION: There is a small amount of evidence supporting CL education, but most of this seems to be related to the practical element of the training. However, there is a lot of evidence in the field of healthcare education from related disciplines which provides additional but important learning tools that may be effectively implemented in CL education.


Subject(s)
Health Personnel , Students , Humans , Teaching
14.
Cont Lens Anterior Eye ; 46(2): 101821, 2023 04.
Article in English | MEDLINE | ID: mdl-36805277

ABSTRACT

INTRODUCTION: Evidence based practice is now an important part of healthcare education. The aim of this narrative literature review was to determine what evidence exists on the efficacy of commonly used teaching and learning and assessment methods in the realm of contact lens skills education (CLE) in order to provide insights into best practice. A summary of the global regulation and provision of postgraduate learning and continuing professional development in CLE is included. METHOD: An expert panel of educators was recruited and completed a literature review of current evidence of teaching and learning and assessment methods in healthcare training, with an emphasis on health care, general optometry and CLE. RESULTS: No direct evidence of benefit of teaching and learning and assessment methods in CLE were found. There was evidence for the benefit of some teaching and learning and assessment methods in other disciplines that could be transferable to CLE and could help students meet the intended learning outcomes. There was evidence that the following teaching and learning methods helped health-care and general optometry students meet the intended learning outcomes; clinical teaching and learning, flipped classrooms, clinical skills videos and clerkships. For assessment these methods were; essays, case presentations, objective structured clinical examinations, self-assessment and formative assessment. There was no evidence that the following teaching and learning methods helped health-care and general optometry students meet the intended learning outcomes; journal clubs and case discussions. Nor was any evidence found for the following assessment methods; multiple-choice questions, oral examinations, objective structured practical examinations, holistic assessment, and summative assessment. CONCLUSION: Investigation into the efficacy of common teaching and learning and assessment methods in CLE are required and would be beneficial for the entire community of contact lens educators, and other disciplines that wish to adapt this approach of evidence-based teaching.


Subject(s)
Clinical Competence , Learning , Humans , Students , Physical Examination , Teaching
15.
Eye Contact Lens ; 49(4): 152-159, 2023 Apr 01.
Article in English | MEDLINE | ID: mdl-36811833

ABSTRACT

ABSTRACT: Since the introduction of silicone hydrogel contact lenses, many silicone-hydrogel materials have been produced, including water-gradient contact lenses with a silicone hydrogel core and a thin hydrogel outer layer (e.g., delefilcon A, verofilcon A, and lehfilcon A). Their properties have been investigated in various studies assessing both the chemical-physical characteristics and the comfort, but the overall picture is not always consistent. In this study, water-gradient technology is reviewed by looking at basic physical properties both in vitro and in vivo and at the interaction with the human ocular surface. Surface and bulk dehydration, surface wetting and dewetting, shear stress, interaction with tear components and with other environmental compounds, and comfort are discussed.


Subject(s)
Contact Lenses, Hydrophilic , Humans , Water , Hydrogels , Silicones , Eye , Hydrogel, Polyethylene Glycol Dimethacrylate , Surface Properties
16.
Cont Lens Anterior Eye ; 46(1): 101533, 2023 02.
Article in English | MEDLINE | ID: mdl-34753686

ABSTRACT

PURPOSE: To evaluate the accuracy and the inter and intra-observer reliability of the centration assessment of extended depth of focus (EDOF) contact lenses (CL) using corneal topography. METHOD: EDOF soft CLs (Mylo, Mark'Ennovy) were fitted on thirty-three myopic students (25 females), aged 19-28 years (22.7 ± 2.0 years). For any EDOF CL, a topography over the CL and a slit lamp (SL) digital picture were taken in random order. For the topographic images, the position of the EDOF CL centre, with respect to the pupil centre, was detected by two different practitioners (one newly graduated and one with more than 20 years of clinical experience respectively) and repeated after 15 days. This measurement was compared to the one taken through the SL, considered as the gold standard, and assessed using the instrument software. RESULTS: EDOF CLs resulted decentred inferiorly and temporally ranging, in the case of slit lamp assessment, between -0.27 ± 0.19 and 0.22 ± 0.23 mm horizontally and between -0.12 ± 0.31 and -0.17 ± 0.34 mm vertically, for the right and left eye respectively. The accuracy of the topographic assessment in determining EDOF CL centration was found to be very good compared to the SL assessment. No differences were found for the left eye, whereas in the right eye, a less temporally decentred position of the CL was detected by the topographical method (p < 0.05). However, this difference appeared clinically negligible (0.14 ± 0.22 mm). Inter-observer reliability (the differences between the two practitioners in assessing the EDOF centre) resulted significant only for the vertical coordinates of the centre position (p < 0.05). Concerning intra-observer reliability, better coefficient of precision and reliability between measurements within the same session were achieved by the more experienced practitioner, as well as a better level of the intraclass correlation coefficient in test-retest. CONCLUSION: The centration of the EDOF CL investigated in this study can be accurately detected by a corneal topography performed over CLs. Inter-observer reliability resulted good whereas the intra-observer reliability resulted partially affected by the level of clinical experience of the practitioner.


Subject(s)
Contact Lenses , Myopia , Female , Humans , Reproducibility of Results , Myopia/diagnosis , Myopia/therapy , Pupil , Corneal Topography
17.
J Optom ; 16(3): 189-198, 2023.
Article in English | MEDLINE | ID: mdl-36207241

ABSTRACT

PURPOSE: This study aimed to translate the Convergence Insufficiency Symptom Survey (CISS) into the Italian language and assess psychometric properties of the translated questionnaire (CISS_I). METHODS: The CISS_I was arranged according to guidelines for a comprehensive multistep methodologic process for translating, adapting, and validating psychometric instruments in health care research. The CISS_I questionnaire was administered to 103 volunteers (21.8 ± 2.2 years), students in higher education, at two different times. A complete optometric evaluation was performed including subjective refraction, best corrected visual acuity, near point of convergence, prism fusional ranges to blur, diplopia and recovery, TNO stereo test and prism cover test for measurement of heterophoria. RESULTS: The performance of the CISS_I in terms of validity showed some points of weakness. Sensitivity was 42%, specificity was 74%, positive predictive value was 27% and negative predictive value was 85%. The area under the ROC curve was 0.672. On the contrary, the results showed good internal consistency of the CISS_I (Cronbach's alpha - α=0.89) and good test-retest reliability (ICC = 0.92). Rasch analysis showed good model fit (all items, except one, with infit and outfit mean square between 0.7 and 1.3), good measurement precision (person separation = 2.66) and good targeting -0,81 logits but also some evidence of multidimensionality. CONCLUSIONS: The CISS_I showed some point of weakness in terms of validity but also good psychometric properties and has been shown to be applicable to an Italian speaking population to quantify the visual discomfort associated with near vision in higher education students. The results show that high CISS_I score is not necessarily linked to convergence insufficiency, while low scores can exclude the presence of this anomaly. The CISS_I can help in interpreting and monitoring convergence insufficiency symptoms in already identified subjects, but it is not suitable for screening a general population of young adults.


Subject(s)
Ocular Motility Disorders , Strabismus , Young Adult , Humans , Psychometrics , Reproducibility of Results , Language , Ocular Motility Disorders/diagnosis , Surveys and Questionnaires
18.
Eye Contact Lens ; 48(9): 369-376, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35971228

ABSTRACT

OBJECTIVE: To investigate eye care practitioners' attitudes and perceptions toward potential interventions that can enhance contact lens (CL) practice across the world, and how this is influenced by their practice setting. METHODS: A self-administered, anonymized survey was constructed in English and then forward and backward translated into six more languages. The survey was distributed online via social media platforms and mailing lists involving reputed international professional bodies. RESULTS: In total, 2,222 responses from 27 countries with sufficient responses were analyzed (53% females, median age- 37 years). Most of the respondents were optometrists (81.9%) and 47.6% were from stand-alone/independent practices. Median working experience in CL prescribing was 11.0 years (IQR: 18.0, 4-22 years). Over two-third of them declared themselves to be very hopeful (22.9%) or hopeful (45.1%) about the future of their CL practice. Among the potential interventions proposed, continuous update of knowledge and skills and competently managing CL-related complications were rated the most important (median score: 9/10 for each). Practitioners working in national/regional retail chains expressed higher proactivity in recommending CLs (9/10) than those in local chains, hospitals, and universities (for all 8/10, P <0.05). National differences were also identified in eye care practitioner attitudes and perceptions ( P <0.05). CONCLUSIONS: The study provided important information to delineate a variety of elements characterizing CL practice across the world. These insights can serve as a basis to design strategies at national and international levels.


Subject(s)
Contact Lenses , Female , Health Knowledge, Attitudes, Practice , Humans , Male , Surveys and Questionnaires , Universities
19.
Cont Lens Anterior Eye ; 45(4): 101490, 2022 08.
Article in English | MEDLINE | ID: mdl-34294534

ABSTRACT

Smoking is a risk factor for the development of microbial keratitis and corneal infiltrates in contact lens (CL) wearers. It is still unknown if this risk is directly associated with the presence of nicotine in the eye and if adherence of nicotine on the CL can enhance these effects. A better understanding of the interaction between nicotine and CL materials could offer insights to explain this risk associated with smoking. The aim of this work was to compare the affinity of nicotine to different soft CL materials. CLs from FDA groups I, II, IV, and V were incubated in a 2-mM nicotine solution for 24 h and then in a 0.9% saline solution for the next 24 h. The amount of absorbed and released nicotine per CL was deduced as a function of time (t) by ultraviolet (UV) spectrophotometry and normalised to the mass of the hydrated CL. The data were described by the equation y = b -a t-1, where a and b are constants, and b represents the mass reached at the plateau after ~ 10 min of exposure. Groups IV and V displayed the highest (0.80 ± 0.09 µg) and lowest (0.27 ± 0.08 µg) nicotine absorption per mg of hydrated CL, respectively. The CL affinity for nicotine could be ascribed to the interaction between the positive charge of nicotine pyrrolidine nitrogen and the negative charges of the CLs, especially for the ionic IV group.


Subject(s)
Contact Lenses, Hydrophilic , Keratitis , Humans , Nicotine
20.
Cont Lens Anterior Eye ; 44(6): 101496, 2021 12.
Article in English | MEDLINE | ID: mdl-34426063

ABSTRACT

AIM: To understand the views of contact lens (CL) practitioners across the globe regarding what they perceive as opportunities and threats in CL practice. METHODS: A self-administered anonymised questionnaire, constructed in English and translated in six more languages, was distributed through reputed international professional bodies and academic institutions worldwide. The questionnaire included items on demographic characteristics, type of practice, and questions designed to explore practitioners' perspective on the future of their CL practice over the next five years. RESULTS: A total of 2408 valid responses were analysed. Multifocal CLs for presbyopia, CLs for myopia control, use of daily disposable (DD) CLs for occasional wear, and biocompatible materials to improve comfort were identified as promising areas of opportunities by practitioners (all 8/10). Respondents from North America, and Europe valued DDCLs for occasional wear moderately more favourable (Median: 9/10 for all) as compared to colleagues in Asia (Median: 8/10, p < 0.001), South America (Median: 8/10, p < 0.01), and Africa (Median: 8/10p < 0.01). Multifocal CLs for presbyopia was perceived as a better opportunity by practitioners in North America and Europe (Median: 9/10 for both), as well as in Australasia (Median: 8/10), in comparison to Asia, Africa, and Middle East (for all Median: 6/10, p < 0.001). Practitioners expressed concerns about the availability of CLs and CL prescriptions online without direct professional involvement (both 9/10). CONCLUSIONS: Overall, the most appealing opportunities for CL practice growth were identified in occasional use of DD CLs, biocompatible materials to reduce CL discomfort, multifocal CLs for presbyopia correction and management of myopia control with CLs. Lack of regulation in CL sales, especially online, seemed to be a constant threat. The insights from this study can be used to design targeted strategies to enhance CL practice across the globe and in specific geographical areas.


Subject(s)
Contact Lenses , Myopia , Presbyopia , Humans , Surveys and Questionnaires , Universities